[PATCH] clk: si5351: fix .recalc_rate for multisynth 6-7

From: Sergej Sawazki
Date: Sun Apr 12 2015 - 08:49:09 EST


MS6 and MS7 do not have the MSx_P3 field. Do the 'params.p3 == 0'
check for MS0-M5 only. See [AN619, p. 6] for details.

Referenced document:
[AN619] Manually Generating an Si5351 Register Map, Rev. 0.4

Signed-off-by: Sergej Sawazki <ce3a@xxxxxx>
---
drivers/clk/clk-si5351.c | 5 ++---
1 file changed, 2 insertions(+), 3 deletions(-)

diff --git a/drivers/clk/clk-si5351.c b/drivers/clk/clk-si5351.c
index 8e90bdd..e7db92f 100644
--- a/drivers/clk/clk-si5351.c
+++ b/drivers/clk/clk-si5351.c
@@ -607,9 +607,6 @@ static unsigned long si5351_msynth_recalc_rate(struct clk_hw *hw,
if (!hwdata->params.valid)
si5351_read_parameters(hwdata->drvdata, reg, &hwdata->params);

- if (hwdata->params.p3 == 0)
- return parent_rate;
-
/*
* multisync0-5: fOUT = (128 * P3 * fIN) / (P1*P3 + P2 + 512*P3)
* multisync6-7: fOUT = fIN / P1
@@ -617,6 +614,8 @@ static unsigned long si5351_msynth_recalc_rate(struct clk_hw *hw,
rate = parent_rate;
if (hwdata->num > 5) {
m = hwdata->params.p1;
+ } else if (hwdata->params.p3 == 0) {
+ return parent_rate;
} else if ((si5351_reg_read(hwdata->drvdata, reg + 2) &
SI5351_OUTPUT_CLK_DIVBY4) == SI5351_OUTPUT_CLK_DIVBY4) {
m = 4;
--
1.9.1

--