Re: [PATCH v3] w1: introduce an ability to specify microseconds bus scanning intervals

From: Evgeniy Polyakov
Date: Wed May 13 2015 - 11:05:33 EST


Hi

12.05.2015, 22:30, "Dmitry Khromov" <dk@xxxxxxxxxxxx>:
> Some of 1-Wire devices commonly associated with physical access control
> systems are attached/generate presence for as short as 100 ms - hence
> the tens-to-hundreds milliseconds scan intervals are required.
>
> Signed-off-by: Dmitry Khromov <dk@xxxxxxxxxxxx>

Greg, please pull it upstream
Acked-by: Evgeniy Polyakov <zbr@xxxxxxxxxxx>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html