Re: [PATCH v2] iio: light: Add support for ROHM RPR0521 sensor
From: Daniel Baluta
Date: Thu May 28 2015 - 10:17:17 EST
<snip>
>> >> +static const struct iio_chan_spec rpr0521_channels[] = {
>> >> + {
>> >> + .type = IIO_INTENSITY,
>> >> + .modified = 1,
>> >> + .address = RPR0521_CHAN_ALS_DATA0,
>> >> + .channel2 = IIO_MOD_LIGHT_BOTH,
>> >> + .info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
>> >> + BIT(IIO_CHAN_INFO_CALIBSCALE),
>> >
>> > why CALIBSCALE and not SCALE?
>>
>> Because this is used to set/get gain, which is used by the hardware
>> to do proper scaling.
>>
>> AFAIK this should be calibscale.
>
> in sysfs-bus-iiof on CALIBSCALE: Hardware applied calibration scale factor
> (assumed to fix production inaccuracies).
>
> this doesn't seem applicable here, it is a gain factor controlling
> measurement resolution
Ok, I see now and it makes sense :).
# echo 1 > in_intensity_ir_calibscale
# cat in_intensity_ir_raw
79
# echo 64 > in_intensity_ir_calibscale
# cat in_intensity_ir_raw
5084
The user should get the same value regardless of the gain :), and in the
above example for x64 gain it should have a 1/64 scale.
<snip>
>> Or we can consider that the chan->type is always valid?
>
> I'd think so; you also assume that chan->address is valid
>
> I suggest to use chan->address to point to a table containing the
> address and the mask
<snip>
>> Which sensors? It means they do not agree with the ABI:
>>
>> http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio#L1131
>
> that 'clarification' was added recently,
> 614e8842ddf5502f0e781f91695bfbc1e1e1d9b6 (with 3.18)
> "Proximity measurement .. by observing reflectivity"
>
> high proximity <-> high reflectivity -- this is the reality of what most
> sensors output (including yours)
>
> proximity and distance are opposite concepts;
> high proximity <-> low distance, and vice versa
>
> the distance part doesn't make sense in the ABI description
At least sx9500 uses this convention and userspace applications rely on this.
>
>> >
>> >> + */
>> >> + if (chan->type == IIO_PROXIMITY)
>> >> + *val = RPR0521_PXS_MAX_VAL - *val;
>> >
>> > really this should be _PROCESSED, not _RAW?
>>
>> I understand and it makes sense. Anyhow, looking at
>> drivers/iio/proximity/sx9500.c
>> it seems to be using _RAW.
>>
>> > how to handle it for buffered reads?
>>
>> Not sure I understand this. Care to add more details :)?
>
>> I would expect that for buffer mode we create an item with 12 realbits and
>> 16 storage bits, and to copy the data from register to buffer.
>
> in buffered mode we want to avoid manipulating the data (i.e. MAX_DATA -
> measurement_value)
>
> since MAX_DATA is not exposed, user mode cannot do this computation and
> _RAW differs from the buffered output
>
> (I assume that we want to have buffered output correspond to _RAW values)
>
>> >> + pm_runtime_set_autosuspend_delay(&client->dev, RPR0521_SLEEP_DELAY_MS);
>> >> + pm_runtime_use_autosuspend(&client->dev);
>> >> +
>> >> + return 0;
>> >
>> > maybe some whitespace here
>> >
>> do you mean remove the new line? :)
>
> add a newline if I predict Jonathan's perference correctly :)
>
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html