[PATCH 1/2] iio: ABI: Clarify proximity output value

From: Daniel Baluta
Date: Thu Jun 11 2015 - 11:47:46 EST


Current description for proximity measurement is ambiguous. While
the first part says that proximity is measured by observing
reflectivity, the second part incorrectly infers that reported values
should behave like a distance.

This is because of AS3935 lightning sensor which uses the proximity
API, while not being a true proximity sensor.

Fixes: 614e8842ddf ("iio: ABI: add clarification for proximity")
Signed-off-by: Daniel Baluta <daniel.baluta@xxxxxxxxx>
---
Documentation/ABI/testing/sysfs-bus-iio | 6 ++----
1 file changed, 2 insertions(+), 4 deletions(-)

diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
index bbed111..70c9b1a 100644
--- a/Documentation/ABI/testing/sysfs-bus-iio
+++ b/Documentation/ABI/testing/sysfs-bus-iio
@@ -1234,10 +1234,8 @@ Description:
object is near the sensor, usually be observing
reflectivity of infrared or ultrasound emitted.
Often these sensors are unit less and as such conversion
- to SI units is not possible. Where it is, the units should
- be meters. If such a conversion is not possible, the reported
- values should behave in the same way as a distance, i.e. lower
- values indicate something is closer to the sensor.
+ to SI units is not possible. Higher proximity measurements
+ indicate closer objects, and vice versa.

What: /sys/.../iio:deviceX/in_illuminance_input
What: /sys/.../iio:deviceX/in_illuminance_raw
--
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html