On Thu, Sep 10, 2015 at 9:28 PM, Ulf Hansson <ulf.hansson@xxxxxxxxxx
<mailto:ulf.hansson@xxxxxxxxxx>> wrote:
>
> On 14 August 2015 at 18:55, Hongtao Wu <wuht06@xxxxxxxxx
<mailto:wuht06@xxxxxxxxx>> wrote:
Yes, most of this data can be removed, such as caps, caps2, base_clk.
However ocr_avail and signal_default_voltage are useful for us.
We can't fetch ocr_avail from external regulator via
mmc_regulator_get_supply,
because our regulator driver can't supply mmc_regulator_get_ocrmask()
interface for MMC driver.
And sometimes our external regulator can not supply 3.0v or 1.8v default
signal voltage that we expect. So this 3.0v or 1.8v default signal
voltage are
mandatory.