Re: [RFC 1/4] Input: edt-ft5x06 - Use max support points to determine how much to read
From: Dmitry Torokhov
Date: Thu Oct 15 2015 - 20:16:40 EST
On Wed, Oct 14, 2015 at 08:58:32PM -0500, Franklin S Cooper Jr. wrote:
>
>
> On 10/14/2015 06:39 PM, Dmitry Torokhov wrote:
> > On Wed, Oct 07, 2015 at 07:21:38AM -0500, fcooper@xxxxxx wrote:
> >> From: Franklin S Cooper Jr <fcooper@xxxxxx>
> >>
> >> Calculate the amount of data that needs to be read for the specified max
> >> number of support points. If the maximum number of support points changes
> >> then the amount that is read from the touch screen controller should
> >> reflect this.
> >>
> >> Signed-off-by: Franklin S Cooper Jr <fcooper@xxxxxx>
> >> ---
> >> drivers/input/touchscreen/edt-ft5x06.c | 6 ++++--
> >> 1 file changed, 4 insertions(+), 2 deletions(-)
> >>
> >> diff --git a/drivers/input/touchscreen/edt-ft5x06.c b/drivers/input/touchscreen/edt-ft5x06.c
> >> index 7239c31..1e0ed6e 100644
> >> --- a/drivers/input/touchscreen/edt-ft5x06.c
> >> +++ b/drivers/input/touchscreen/edt-ft5x06.c
> >> @@ -178,14 +178,16 @@ static irqreturn_t edt_ft5x06_ts_isr(int irq, void *dev_id)
> >> cmd = 0xf9; /* tell the controller to send touch data */
> >> offset = 5; /* where the actual touch data starts */
> >> tplen = 4; /* data comes in so called frames */
> >> - datalen = 26; /* how much bytes to listen for */
> >> +
> >> + /* how many bytes to listen for */
> >> + datalen = tplen * MAX_SUPPORT_POINTS + offset + 1;
> >> break;
> >>
> >> case M09:
> >> cmd = 0x02;
> >> offset = 1;
> >> tplen = 6;
> >> - datalen = 29;
> >> + datalen = tplen * MAX_SUPPORT_POINTS - cmd + 1;
> >> break;
> >
> > Hmm, why would formulae for datalen be different depending on the
> > firmware? And I think original 29 it too low: we need 30 bytes for 5
> > contacts + 1 to account for offset.
> So based on the current ISR we don't care about the touch weight and
> which are the last two registers for each touch point. So for the last
> touchpoint we really don't need to read the extra two registers (-2).
This is really not obvious. I do not think we'd see any performance
degradation if we actually read the whole last touchpoint.
> We need +1 simply for the fact that we read the register at location
> cmd.
I am not sure I follow this. We do not reference anything past
rdbuf[(MAX_SUPPORT_POINTS - 1) * tplen + offset] and
our offset takes care of the start position, so why exactly we need the
+1? Ah, CRC is in the extra byte.
Can we unify the calculation to be:
datalen = tplen * MAX_SUPPORT_POINTS + offset + crc_len;
By the way, what version of firmware you tested your changes with?
>
> So 6 * 5 - 2 + 1 which is how we get to 29. The formula looks slightly
> different because the registers we are reading are very close to zero
> so the math works out to equal the equation I used for M09.
>
> M06 since tplen = 4 then all four registers are used in the ISR per touch
> point. Plus the offset and plus 1 again to account for the fact we are reading
> the cmd register. But once again it would be nice if someone can confirm this.
> >
> > I also wonder why we need extra 1 byte in M06 case.
> >
> > Lothar?
> >
> > Thanks.
> >
>
Thanks.
--
Dmitry
--
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/