On Mon, Jan 04, 2016 at 11:54:40AM +0000, Suzuki K. Poulose wrote:
Instead of hard coding the period we program on the PMU
counters, define a symbol.
- u64 val = 1ULL << 31;
- local64_set(&hwc->prev_count, val);
- pmu_write_counter(event, val);
+ local64_set(&hwc->prev_count, CCI_CNTR_PERIOD);
+ pmu_write_counter(event, CCI_CNTR_PERIOD);
I think this is a little misleading (and confusing), as we're conflating
the period with its inverse. This wouldn't work for any other value of
CCI_CNTR_PERIOD.
Perhaps s/PERIOD/START_VAL/, leaving everything else as-is?