On Tuesday 12 January 2016 13:46:32 Srinivas Kandagatla wrote:Labels are good and works for me.
};
+ smd {
+ rpm {
+ rpm-requests {
+ pm8916-regulators {
+
+ vdd_l1_l2_l3-supply = <&pm8916_s3>;
+ vdd_l5-supply = <&pm8916_s3>;
+ vdd_l4_l5_l6-supply = <&pm8916_s4>;
+ vdd_l7-supply = <&pm8916_s4>;
+
If you're nested this deeply, you should consider using labels, e.g.
/ {These regulators are identified by the node names, and have no addresses associated with it as control goes over SMD based IPC to the rpm.
...
smd {
rpm {
rpm-requests {
regulators: pm8916-regulators {
};
};
};
};
...
};
®ulators {
vdd_l1_l2_l3-supply = <&pm8916_s3>;
vdd_l5-supply = <&pm8916_s3>;
vdd_l4_l5_l6-supply = <&pm8916_s4>;
vdd_l7-supply = <&pm8916_s4>;
s1 {
regulator-min-microvolt = <375000>;
regulator-max-microvolt = <1562000>;
};
s3 {
regulator-min-microvolt = <375000>;
regulator-max-microvolt = <1562000>;
};
...
};
btw, it seems odd to me that all those nodes under 'smd'
have names but no addresses.
Arnd