Re: [PATCH net-next 03/10] net: mvneta: bm: add support for hardware buffer management
From: Marcin Wojtas
Date: Tue Jan 12 2016 - 15:12:33 EST
Hi Gregory,
I have two remarks to my own code. Please let me know before patch v2,
I will provide you with corrected version (I already did it locally).
> @@ -1556,17 +1777,20 @@ static void mvneta_rxq_drop_pkts(struct mvneta_port *pp,
> int rx_done, i;
>
> rx_done = mvneta_rxq_busy_desc_num_get(pp, rxq);
> + if (rx_done)
> + mvneta_rxq_desc_num_update(pp, rxq, rx_done, rx_done);
> +
> + if (pp->bm_priv)
> + return;
> +
This is wrong - buffers that are supposed to be dropped should return
to bm_pool.
> @@ -1587,23 +1812,35 @@ static int mvneta_rx(struct mvneta_port *pp, int rx_todo,
>
> rx_done = 0;
>
> + bm_in_use = pp->bm_priv ? true : false;
> +
> /* Fairness NAPI loop */
> while (rx_done < rx_todo) {
> struct mvneta_rx_desc *rx_desc = mvneta_rxq_next_desc_get(rxq);
> + struct mvneta_bm_pool *bm_pool = NULL;
> struct sk_buff *skb;
> unsigned char *data;
> dma_addr_t phys_addr;
> - u32 rx_status;
> + u32 rx_status, frag_size;
> int rx_bytes, err;
> + u8 pool_id;
>
> rx_done++;
> rx_status = rx_desc->status;
> rx_bytes = rx_desc->data_size - (ETH_FCS_LEN + MVNETA_MH_SIZE);
> data = (unsigned char *)rx_desc->buf_cookie;
> phys_addr = rx_desc->buf_phys_addr;
> + if (bm_in_use) {
> + pool_id = MVNETA_RX_GET_BM_POOL_ID(rx_desc);
> + bm_pool = &pp->bm_priv->bm_pools[pool_id];
> + }
>
> if (!mvneta_rxq_desc_is_first_last(rx_status) ||
> (rx_status & MVNETA_RXD_ERR_SUMMARY)) {
> + /* Return the buffer to the pool */
> + if (bm_in_use)
> + mvneta_bm_pool_put_bp(pp->bm_priv, bm_pool,
> + rx_desc->buf_phys_addr);
> err_drop_frame:
> dev->stats.rx_errors++;
> mvneta_rx_error(pp, rx_desc);
> @@ -1633,25 +1870,38 @@ static int mvneta_rx(struct mvneta_port *pp, int rx_todo,
> rcvd_pkts++;
> rcvd_bytes += rx_bytes;
>
> + /* Return the buffer to the pool */
> + if (bm_in_use)
> + mvneta_bm_pool_put_bp(pp->bm_priv, bm_pool,
> + rx_desc->buf_phys_addr);
> +
> /* leave the descriptor and buffer untouched */
> continue;
> }
>
> /* Refill processing */
> - err = mvneta_rx_refill(pp, rx_desc);
> + err = bm_in_use ? mvneta_bm_pool_refill(pp->bm_priv, bm_pool) :
> + mvneta_rx_refill(pp, rx_desc);
> if (err) {
> netdev_err(dev, "Linux processing - Can't refill\n");
> rxq->missed++;
> goto err_drop_frame;
Wrong - on refill fail, original buffer should be returned to bm_pool.
Same case is, when netdev_alloc_skb_ip_align fail inside copybreak
(this should also be fixed).
Best regards,