[PATCH v4 2/2] power: add documentation for ACT8945A's charger DT bindings

From: Wenyou Yang
Date: Tue Jan 12 2016 - 23:30:22 EST


This patch adds documentation for the DT bindings of the charger
subdevice of ACT8945A MFD.

Signed-off-by: Wenyou Yang <wenyou.yang@xxxxxxxxx>
---

Changes in v4:
- change the properties with more legible name, clearer description.

Changes in v3: None
Changes in v2: None

.../devicetree/bindings/power/act8945a-charger.txt | 33 ++++++++++++++++++++
1 file changed, 33 insertions(+)
create mode 100644 Documentation/devicetree/bindings/power/act8945a-charger.txt

diff --git a/Documentation/devicetree/bindings/power/act8945a-charger.txt b/Documentation/devicetree/bindings/power/act8945a-charger.txt
new file mode 100644
index 0000000..2055da7
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/act8945a-charger.txt
@@ -0,0 +1,33 @@
+Device-Tree bindings for charger of Active-semi ACT8945A Multi-Function Device
+
+Required properties:
+ - compatible: "active-semi,act8945a-charger".
+ - active-semi,chglev-gpios: charge current level phandle with args
+ as described in ../gpio/gpio.txt.
+
+Optional properties:
+ - active-semi,check-battery-temperature: boolean to check the battery
+ temperature or not.
+ - active-semi,input-voltage-threshold-microvolt: unit: mV;
+ Specifies the charger's input over-voltage threshold value;
+ The value can be: 6600, 7000, 7500, 8000; default: 6600
+ - active-semi,precondition-timeout: unit: minutes;
+ Specifies the charger's PRECONDITION safety timer setting value;
+ The value can be: 40, 60, 80, 0; If 0, it means to disable this timer;
+ default: 40.
+ - active-semi,total-timeout: unit: hours;
+ Specifies the charger's total safety timer setting value;
+ The value can be: 3, 4, 5, 0; If 0, it means to disable this timer;
+ default: 3.
+
+Example:
+
+ charger {
+ compatible = "active-semi,act8945a-charger";
+ pinctrl-names = "default";
+ pinctrl-0 = <&pinctrl_charger_chglev>;
+ active-semi,chglev-gpios = <&pioA 12 GPIO_ACTIVE_HIGH>;
+ active-semi,input-voltage-threshold-microvolt = <6600>;
+ active-semi,precondition-timeout = <40>;
+ active-semi,total-timeout = <3>;
+ };
--
1.7.9.5