Re: Regard of thermal power allocator's coefficients
From: Leo Yan
Date: Sun Feb 14 2016 - 23:48:27 EST
Hi Eduardo,
Thanks for replying.
On Sun, Feb 14, 2016 at 09:12:19AM -0800, Eduardo Valentin wrote:
> On Sun, Feb 14, 2016 at 07:00:41PM +0800, Leo Yan wrote:
[...]
> > So want to firstly to confirm if should we pass coefficients by using
> > device tree? Is someone working on related work for this?
>
> We pass the sustainable power, but not the coefficients. IIRC, the IPA
> coefficients were considered (SW) implementation details. Sustainable power,
> on the other hand, still describes hardware capabilities.
>
> So, I don't think they will go via DT.
I'd like clarify one thing: "coefficients" are used to calculate
static leakage and dynamic power but not PID's term constants. They
are quite dependent on silicon's process; this is similiar with
sustainable power. So do you think we should take these "coefficients"
as software paramters?
The code is written in drivers/thermal/hisi_thermal.c like below:
---8<---
struct cluster_power_coefficients cluster_data = {
.dyn_coeff = 266,
.static_cpu = 14,
.static_cluster = 5,
};
/* voltage in uV and temperature in mC */
static int get_static_power(cpumask_t *cpumask, int interval,
unsigned long u_volt, u32 *power)
{
int nr_cpus = cpumask_weight(cpumask);
*power = nr_cpus * cluster_data.static_cpu;
*power += 2 * cluster_data.static_cluster;
return 0;
}
static int hisi_thermal_register_cooling_device(struct platform_device *pdev,
struct hisi_thermal_data *data)
{
struct device_node *np;
np = of_find_node_by_name(NULL, "cluster0");
if (!np) {
dev_err(&pdev->dev, "Cluster0 node not founds\n");
return -ENODEV;
}
data->cdevs = of_cpufreq_power_cooling_register(np,
cpu_present_mask, cluster_data.dyn_coeff,
get_static_power);
if (IS_ERR(data->cdevs)) {
dev_err(&pdev->dev,
"Error registering cooling device: %ld\n",
PTR_ERR(data->cdevs));
return PTR_ERR(data->cdevs);
}
return 0;
}
Thanks,
Leo Yan