Quoting Lars Persson (2016-02-14 00:03:06)
Are all of those clks going to individual DT nodes with clock-cells = 0?
On 02/12/2016 05:39 PM, Rob Herring wrote:
On Thu, Feb 11, 2016 at 05:01:03PM +0100, Lars Persson wrote:It will have 17 clocks declared in the device tree and three
Add device tree documentation for the main PLL in the Artpec-6 SoC.Roughly how many clocks does this SoC have?
SoC-specific clock drivers.
If so, I wonder if you should be targeting a clock-controller style
binding description, with a node that represents the clock-controller IP
block, with clock-cells >= 1. It really comes down to whether or not
these clock controls exist in the same IP block.
We still prefer to fully describe the static parts of the the clock tree in the DT. Will you accept this ?
You mentioned three distinct clock drivers. So possibly three clock
controller nodes in DT then?
No.
Is there a reference manual/register map available for this SoC?
Will be fixed in v2.Please specify that this is based on the clock provider binding inSigned-off-by: Lars Persson <larper@xxxxxxxx>
---
Documentation/devicetree/bindings/clock/artpec6.txt | 16 ++++++++++++++++
1 file changed, 16 insertions(+)
create mode 100644 Documentation/devicetree/bindings/clock/artpec6.txt
diff --git a/Documentation/devicetree/bindings/clock/artpec6.txt b/Documentation/devicetree/bindings/clock/artpec6.txt
new file mode 100644
index 0000000..521fec8
--- /dev/null
+++ b/Documentation/devicetree/bindings/clock/artpec6.txt
@@ -0,0 +1,16 @@
+* Clock bindings for Axis ARTPEC-6 chip
Documentation/devicetree/bindings/clock/clock-bindings.txt
Regards,
Mike
+
+Required properties:
+- #clock-cells: Should be <0>
+- compatible: Should be "axis,artpec6-pll1-clock"
+- reg: Address and length of the DEVSTAT register.
+- clocks: The PLL's input clock.
+
+Examples:
+
+pll1_clk: pll1_clk {
+ #clock-cells = <0>;
+ compatible = "axis,artpec6-pll1-clock";
+ reg = <0xf8000000 4>;
+ clocks = <&ext_clk>;
+};
--
2.1.4