Am 01.03.2016 um 15:43 schrieb Sudeep Holla:
On 29/02/16 23:44, Andreas FÃrber wrote:
+ psci {
+ compatible = "arm,psci";
Any particular reason why PSCI v0.2 or above is not supported on this
platform. PSCI v0.1 is very old now and I assume this platform is
relatively new.
I am not affiliated with Amlogic or Tronsmart, so I cannot answer why.
+ method = "smc";
+ cpu_suspend = <0xc4000001>;
+ cpu_off = <0x84000002>;
+ cpu_on = <0xc4000003>;
+ migrate = <0xc4000005>;
Atleast the functions ids look like v0.2 or above. So check if it's
actually v0.2 or above
If you let me know how! Just change the compatible string to -0.2 and
wait for some big boom or watch out for any misbehavior in particular?
Are there any memory locations to check the version or something visible
in U-Boot source code indicating it?