[PATCH] clk: ti: dra7-atl-clock: Fix of_node reference counting

From: Peter Ujfalusi
Date: Fri Mar 11 2016 - 09:16:23 EST


of_find_node_by_name() will call of_node_put() on the node so we need to
get it first to avoid warnings.
The cfg_node needs to be put after we have finished processing the
properties.

Signed-off-by: Peter Ujfalusi <peter.ujfalusi@xxxxxx>
---
drivers/clk/ti/clk-dra7-atl.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/clk/ti/clk-dra7-atl.c b/drivers/clk/ti/clk-dra7-atl.c
index 2e14dfb588f4..c77333230bdf 100644
--- a/drivers/clk/ti/clk-dra7-atl.c
+++ b/drivers/clk/ti/clk-dra7-atl.c
@@ -265,6 +265,7 @@ static int of_dra7_atl_clk_probe(struct platform_device *pdev)

/* Get configuration for the ATL instances */
snprintf(prop, sizeof(prop), "atl%u", i);
+ of_node_get(node);
cfg_node = of_find_node_by_name(node, prop);
if (cfg_node) {
ret = of_property_read_u32(cfg_node, "bws",
@@ -278,6 +279,7 @@ static int of_dra7_atl_clk_probe(struct platform_device *pdev)
atl_write(cinfo, DRA7_ATL_AWSMUX_REG(i),
cdesc->aws);
}
+ of_node_put(cfg_node);
}

cdesc->probed = true;
--
2.7.2