Re: Warnings for invalid VDD (sdhci-s3c)
From: Jisheng Zhang
Date: Thu Mar 24 2016 - 04:28:58 EST
Hi,
On Thu, 24 Mar 2016 17:09:27 +0900 Jaehoon Chung wrote:
> Hi,
>
> On 03/24/2016 04:58 PM, Jisheng Zhang wrote:
> > Hi,
> >
> > On Thu, 24 Mar 2016 16:28:56 +0900 Krzysztof Kozlowski wrote:
> >
> >> Hi,
> >>
> >> After 918f4cbd4340 ("mmc: sdhci: restore behavior when setting VDD via
> >> external regulator") On Trats2 board I see warnings for invalid VDD
> >> value (2.8V):
> >>
> >> [ 3.119656] ------------[ cut here ]------------
> >> [ 3.119666] WARNING: CPU: 3 PID: 90 at
> >> ../drivers/mmc/host/sdhci.c:1234 sdhci_do_set_ios+0x4cc/0x5e0
> >> [ 3.119669] mmc0: Invalid vdd 0x10
> >
> > Per my understanding, the wrong vdd indicates a wrong ocr, what's the voltage of
> > this host's vmmc regulator?
>
> As i know, it's fixed-voltage with gpio on trats2. It's 2.8V.
> I didn't check this entirely..need to check ocr value.
>
I may know the reason. the vmmc is 2.8v, then mmc_regulator_get_supply() convert
the value to a ocr as 0x10. The key here is that the 2.8v is invalid in SDHCI
case and isn't accepted by current sdhci driver.
I dunno the elegant solution to handle this case, let's wait for sdhci maintainers
idea.
Thanks,
Jisheng