Re: [PATCH] regulator: twl: Enable regulators over the powerbus as well
From: Mark Brown
Date: Fri Mar 25 2016 - 18:29:16 EST
On Fri, Mar 25, 2016 at 09:19:12PM +0100, Sebastian Reichel wrote:
> On Fri, Mar 25, 2016 at 06:20:17PM +0000, Mark Brown wrote:
> > Then there is a constraint that the regulators must be in normal mode
> > and this needs to be expressed in the machine constraints.
> As in adding "regulator-initial-mode = <TWL4030_OPMODE_NORMAL>;" to
> the regulator's DT node (and providing an of_map_mode method in the
> twl-regulator driver)?
Yes, that sounds like a sensible way to do it.
Attachment:
signature.asc