Re: ARC dw-mshc binding compat string

From: Alexey Brodkin
Date: Sat Mar 26 2016 - 13:53:07 EST


Hi Marek, Vladimir,

26 марта 2016 г. 20:30 пользователь Marek Vasut <marex@xxxxxxx> написал:
>
> On 03/26/2016 06:26 PM, Vlad

On 03/26/2016 06:26 PM, Vladimir Zapolskiy wrote:
> On 26.03.2016 12:14, Marek Vasut wrote:
>> Hi!
>>
>> I noticed that arch/arc/boot/dts/axs10x_mb.dtsi uses "altr," prefix in
>> the DT compatible string:
>>
>> mmc@0x15000 {
>> compatible = "altr,socfpga-dw-mshc";
>> reg = < 0x15000 0x400 >;
>> num-slots = < 1 >;
>> fifo-depth = < 16 >;
>> card-detect-delay = < 200 >;
>> clocks = <&apbclk>, <&mmcclk>;
>> clock-names = "biu", "ciu";
>> interrupts = < 7 >;
>> bus-width = < 4 >;
>> };
>>
>> I don't think this is OK, since ARC is unrelated to Altera, which is
>> what the "altr," prefix stands for. I think the socfpga-dw-mshc shim
>> should be extended with another compatibility string, something like
>> "snps,arc-dw-mshc" and the axs10x_mb.dtsi should be adjusted
>> accordingly. What do you think ?
>>
>
> There is "snps,dw-mshc" described in
> Documentation/devicetree/bindings/mmc/synopsys-dw-mshc.txt and supported by
> dw_mmc host controller driver.

Thanks, that's even better.

btw what do you think of using altr, prefix on non-altera system, that
doesn't seem ok, right ?


--
Best regards,
Marek Vasut