[PATCH 3/9] arm64: tegra: set critical trips for Tegra132

From: Wei Ni
Date: Thu Mar 31 2016 - 04:44:17 EST


Set general "critical" trip temperatures for cpu, gpu, mem and pllx
thermal zones on Tegra132, these trips can trigger shut down or reset.

Signed-off-by: Wei Ni <wni@xxxxxxxxxx>
---
arch/arm64/boot/dts/nvidia/tegra132.dtsi | 62 +++++++++++++++++++++++++++++++-
1 file changed, 61 insertions(+), 1 deletion(-)

diff --git a/arch/arm64/boot/dts/nvidia/tegra132.dtsi b/arch/arm64/boot/dts/nvidia/tegra132.dtsi
index bd5010a7cba4..40fe2bcb55d2 100644
--- a/arch/arm64/boot/dts/nvidia/tegra132.dtsi
+++ b/arch/arm64/boot/dts/nvidia/tegra132.dtsi
@@ -729,7 +729,7 @@

soctherm: thermal-sensor@0,700e2000 {
compatible = "nvidia,tegra132-soctherm";
- reg = <0x0 0x700e2000 0x0 0x1000>;
+ reg = <0x0 0x700e2000 0x0 0x600>;
interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
<&tegra_car TEGRA124_CLK_SOC_THERM>;
@@ -746,6 +746,21 @@

thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
+
+ trips {
+ cpu_shutdown_trip {
+ temperature = <105000>;
+ hysteresis = <1000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ /*
+ * There are currently no cooling maps,
+ * because there are no cooling devices.
+ */
+ };
};
mem {
polling-delay-passive = <0>;
@@ -753,6 +768,21 @@

thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_MEM>;
+
+ trips {
+ mem_shutdown_trip {
+ temperature = <101000>;
+ hysteresis = <1000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ /*
+ * There are currently no cooling maps,
+ * because there are no cooling devices.
+ */
+ };
};
gpu {
polling-delay-passive = <1000>;
@@ -760,6 +790,21 @@

thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_GPU>;
+
+ trips {
+ gpu_shutdown_trip {
+ temperature = <101000>;
+ hysteresis = <1000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ /*
+ * There are currently no cooling maps,
+ * because there are no cooling devices.
+ */
+ };
};
pllx {
polling-delay-passive = <0>;
@@ -767,6 +812,21 @@

thermal-sensors =
<&soctherm TEGRA124_SOCTHERM_SENSOR_PLLX>;
+
+ trips {
+ pllx_shutdown_trip {
+ temperature = <105000>;
+ hysteresis = <1000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ /*
+ * There are currently no cooling maps,
+ * because there are no cooling devices.
+ */
+ };
};
};

--
1.9.1