[PATCH 3.19.y-ckt 074/170] x86/PCI: Mark Broadwell-EP Home Agent & PCU as having non-compliant BARs
From: Kamal Mostafa
Date: Fri Apr 01 2016 - 21:26:26 EST
3.19.8-ckt18 -stable review patch. If anyone has any objections, please let me know.
---8<------------------------------------------------------------
From: Bjorn Helgaas <bhelgaas@xxxxxxxxxx>
commit b894157145e4ac7598d7062bc93320898a5e059e upstream.
The Home Agent and PCU PCI devices in Broadwell-EP have a non-BAR register
where a BAR should be. We don't know what the side effects of sizing the
"BAR" would be, and we don't know what address space the "BAR" might appear
to describe.
Mark these devices as having non-compliant BARs so the PCI core doesn't
touch them.
Signed-off-by: Bjorn Helgaas <bhelgaas@xxxxxxxxxx>
Tested-by: Andi Kleen <ak@xxxxxxxxxxxxxxx>
Signed-off-by: Kamal Mostafa <kamal@xxxxxxxxxxxxx>
---
arch/x86/pci/fixup.c | 7 +++++++
1 file changed, 7 insertions(+)
diff --git a/arch/x86/pci/fixup.c b/arch/x86/pci/fixup.c
index 9a2b710..f16af96 100644
--- a/arch/x86/pci/fixup.c
+++ b/arch/x86/pci/fixup.c
@@ -553,3 +553,10 @@ static void twinhead_reserve_killing_zone(struct pci_dev *dev)
}
}
DECLARE_PCI_FIXUP_HEADER(PCI_VENDOR_ID_INTEL, 0x27B9, twinhead_reserve_killing_zone);
+
+static void pci_bdwep_bar(struct pci_dev *dev)
+{
+ dev->non_compliant_bars = 1;
+}
+DECLARE_PCI_FIXUP_EARLY(PCI_VENDOR_ID_INTEL, 0x6fa0, pci_bdwep_bar);
+DECLARE_PCI_FIXUP_EARLY(PCI_VENDOR_ID_INTEL, 0x6fc0, pci_bdwep_bar);
--
2.7.4