Re: [PATCH 1/2] regulator: DT: Add support to scale ramp delay based on platform behavior

From: Laxman Dewangan
Date: Tue Apr 12 2016 - 09:40:36 EST



On Tuesday 12 April 2016 06:32 AM, Mark Brown wrote:
* PGP Signed by an unknown key

On Tue, Apr 05, 2016 at 01:31:41PM +0530, Laxman Dewangan wrote:
On Friday 01 April 2016 09:41 PM, Mark Brown wrote:
Now there is not really equation that how it control dV/dt with required
current vs regulator's current limit current limit.
I'm having a hard time tying this in with what you're saying. You're
saying we have a predictable limit based on some hard maximum inrush
current but we can't tell what that limit is? What I'd expect is that
we'd get the spec limit up to some maximum and then cap out at that.


I have put my understanding based on datasheet and observation but it seems I am missing some important information which is making difficult to understand further here.
We are not crossing the maximum limit of the load on the rail per datasheet. We just changed the output capacitor in the platforms and saw deviation.

I think I need to go again to Vendor to find out that why changing of capacitor making the deviation in ramp delay and what is the relation. Probably, that may help here.