Re: [PATCH] Documentation: Add ebc-c384_wdt watchdog-parameters.txt entry

From: Guenter Roeck
Date: Wed May 11 2016 - 10:20:11 EST


On Wed, May 11, 2016 at 08:47:46AM -0400, William Breathitt Gray wrote:
> The WinSystems EBC-C384 watchdog timer driver supports two module
> parameters: timeout and nowayout. These parameters should be documented
> in the watchdog-parameters.txt file.
>
> Signed-off-by: William Breathitt Gray <vilhelm.gray@xxxxxxxxx>

Reviewed-by: Guenter Roeck <linux@xxxxxxxxxxxx>

> ---
> Documentation/watchdog/watchdog-parameters.txt | 4 ++++
> 1 file changed, 4 insertions(+)
>
> diff --git a/Documentation/watchdog/watchdog-parameters.txt b/Documentation/watchdog/watchdog-parameters.txt
> index c161399..a8d3642 100644
> --- a/Documentation/watchdog/watchdog-parameters.txt
> +++ b/Documentation/watchdog/watchdog-parameters.txt
> @@ -86,6 +86,10 @@ nowayout: Watchdog cannot be stopped once started
> davinci_wdt:
> heartbeat: Watchdog heartbeat period in seconds from 1 to 600, default 60
> -------------------------------------------------
> +ebc-c384_wdt:
> +timeout: Watchdog timeout in seconds. (1<=timeout<=15300, default=60)
> +nowayout: Watchdog cannot be stopped once started
> +-------------------------------------------------
> ep93xx_wdt:
> nowayout: Watchdog cannot be stopped once started
> timeout: Watchdog timeout in seconds. (1<=timeout<=3600, default=TBD)
> --
> 2.7.3
>