Re: [RFC][PATCH 4/7] sched: Replace sd_busy/nr_busy_cpus with sched_domain_shared

From: Peter Zijlstra
Date: Tue May 17 2016 - 06:20:23 EST


On Mon, May 16, 2016 at 04:00:32PM +0200, Peter Zijlstra wrote:
> On Fri, May 13, 2016 at 10:12:26AM +1000, Michael Neuling wrote:
>
> > > Basically; and if so, if its cheap enough to shoot a task to an idle
> > > core to avoid queueing. Assuming there still is some cache residency on
> > > the old core, the inter-core fill should be much cheaper than fetching
> > > it off package (either remote cache or dram).
> >
> > So I think that will apply on POWER8.
> >
> > In 10.4.2 it says "The L3.1 ECO Caches will be snooped and provide
> > intervention data similar to the L2 and L3.0 caches on the
> > chip"  That should be much faster than going to another chip or DIMM.
> >
> > So migrating to another core on the same chip should be faster than off
> > chip.
>
> OK; so something like the below might be what you want to play with.
>
> ---

Maybe even something like so; which would make Power <= 6 use the
default topology and result in a shared LLC between the on package cores
etc..

Power7 is then special for not having a shared L3 but having the
asymmetric SMT thing and Power8 again gains the shared L3 while
retaining the asymmetric SMT stuff.

---
arch/powerpc/kernel/smp.c | 34 +++++++++++++++++++++++++++++++++-
1 file changed, 33 insertions(+), 1 deletion(-)

diff --git a/arch/powerpc/kernel/smp.c b/arch/powerpc/kernel/smp.c
index 55c924b65f71..09ce422fc29c 100644
--- a/arch/powerpc/kernel/smp.c
+++ b/arch/powerpc/kernel/smp.c
@@ -782,6 +782,23 @@ static struct sched_domain_topology_level powerpc_topology[] = {
{ NULL, },
};

+static struct sched_domain_topology_level powerpc8_topology[] = {
+#ifdef CONFIG_SCHED_SMT
+ { cpu_smt_mask, powerpc_smt_flags, SD_INIT_NAME(SMT) },
+#endif
+#ifdef CONFIG_SCHED_MC
+ /*
+ * Model the L3.1 cache and sets the LLC as the whole package.
+ *
+ * This also ensures we try and move woken tasks to idle cores inside
+ * the package to avoid queueing.
+ */
+ { cpu_coregroup_mask, cpu_core_flags, SD_INIT_NAME(MC) },
+#endif
+ { cpu_cpu_mask, SD_INIT_NAME(DIE) },
+ { NULL, },
+};
+
void __init smp_cpus_done(unsigned int max_cpus)
{
cpumask_var_t old_mask;
@@ -806,7 +823,22 @@ void __init smp_cpus_done(unsigned int max_cpus)

dump_numa_cpu_topology();

- set_sched_topology(powerpc_topology);
+ if (cpu_has_feature(CPU_FTRS_POWER7)) {
+ /*
+ * Power7 topology is special because it doesn't have
+ * a shared L3 between cores and has the ASYM(metric)
+ * SMT thing.
+ */
+ set_sched_topology(powerpc_topology);
+ }
+
+ if (cpu_has_feature(CPU_FTRS_POWER8)) {
+ /*
+ * Power8 differs from Power7 in that it does sort-of
+ * have a shared L3 again.
+ */
+ set_sched_topology(powerpc8_topology);
+ }

}