Re: [PATCH 1/2] clk: exynos5420: Set ID for aclk333 gate clock

From: Krzysztof Kozlowski
Date: Wed May 25 2016 - 03:11:24 EST


On 05/24/2016 07:41 PM, Javier Martinez Canillas wrote:
> The aclk333 clock needs to be ungated during the MFC power domain switch,
> so set the clock ID to allow the Exynos power domain logic to lookup this
> clock if is defined in the MFC PD device tree node.
>
> Signed-off-by: Javier Martinez Canillas <javier@xxxxxxxxxxxxxxx>
> ---
>
> drivers/clk/samsung/clk-exynos5420.c | 2 +-
> 1 file changed, 1 insertion(+), 1 deletion(-)

Reviewed-by: Krzysztof Kozlowski <k.kozlowski@xxxxxxxxxxx>

Best regards,
Krzysztof