[PATCH 14/14] regulator: pwm: Document pwm-dutycycle-unit and pwm-dutycycle-range

From: Boris Brezillon
Date: Fri Jun 03 2016 - 04:23:45 EST


Document the pwm-dutycycle-unit and pwm-dutycycle-range properties.

Signed-off-by: Boris Brezillon <boris.brezillon@xxxxxxxxxxxxxxxxxx>
---
.../devicetree/bindings/regulator/pwm-regulator.txt | 12 ++++++++++++
1 file changed, 12 insertions(+)

diff --git a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
index ed936f0..5303235 100644
--- a/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
+++ b/Documentation/devicetree/bindings/regulator/pwm-regulator.txt
@@ -34,6 +34,18 @@ Only required for Voltage Table Mode:
First cell is voltage in microvolts (uV)
Second cell is duty-cycle in percent (%)

+Optional properties for Continuous mode:
+- pwm-dutycycle-unit: Integer value encoding the dutycycle unit. If not
+ defined, <100> is assumed, meaning that
+ pwm-dutycycle-range contains values expressed in
+ percent.
+
+- pwm-dutycycle-range: Should contain 2 entries. The first entry is encoding
+ the dutycycle for regulator-min-microvolt and the
+ second one the dutycycle for regulator-max-microvolt.
+ Dutycyle values are expressed in pwm-dutycycle-unit.
+ If not defined, <0 100> is assumed.
+
NB: To be clear, if voltage-table is provided, then the device will be used
in Voltage Table Mode. If no voltage-table is provided, then the device will
be used in Continuous Voltage Mode.
--
2.7.4