Re: [PATCH v2] clk: fixed-factor: add optional dt-binding clock-flags

From: Rob Herring
Date: Tue Jun 28 2016 - 16:55:33 EST


On Fri, Jun 24, 2016 at 01:12:52PM +0900, Jongsung Kim wrote:
> There is no way to set additional flags for a DT-initialized fixed-
> factor-clock, and it can be problematic i.e., when the clock rate
> needs to be changed. [1][2]
>
> This patch introduces an optional dt-binding named "clock-flags" to
> be used for passing any needed flags from dts.

I don't think we want this in DT. If we did, the flags would need some
documentation about what the flags mean.