Re: [PATCH v2] clk: fixed-factor: add optional dt-binding clock-flags
From: Jongsung Kim
Date: Wed Jun 29 2016 - 03:23:01 EST
On 2016ë 06ì 29ì 06:18, Michael Turquette wrote:
> Quoting Rob Herring (2016-06-28 13:55:18)
>> On Fri, Jun 24, 2016 at 01:12:52PM +0900, Jongsung Kim wrote:
>>> There is no way to set additional flags for a DT-initialized fixed-
>>> factor-clock, and it can be problematic i.e., when the clock rate
>>> needs to be changed. [1][2]
>>>
>>> This patch introduces an optional dt-binding named "clock-flags" to
>>> be used for passing any needed flags from dts.
>> I don't think we want this in DT. If we did, the flags would need some
>> documentation about what the flags mean.
> Flags are specific to Linux implementation, so I agree with Rob. Better
> to create a compatible string for your hardware that bakes in the flags.
Thank you for your comment, Mike. This conversation starts from lacking method to set CLK_SET_RATE_PARENT from DT. I understand compatible string can be a solution. But.. if someone starts talking about lacking method to set another flag, i.e., CLK_SET_PARENT_GATE, then we'll need another compatible string list.
How do you think about defining possible required subset of the flags and using some more neutral flag-names acceptable in DT?