Re: [PATCH] i2c: bcm2835: Set up the clock stretching timeout at boot.
From: Wolfram Sang
Date: Fri Jul 22 2016 - 03:27:55 EST
On Sun, Jul 03, 2016 at 06:02:32PM -0700, Eric Anholt wrote:
> Wolfram Sang <wsa@xxxxxxxxxxxxx> writes:
>
> >> + /*
> >> + * SMBUS says "Devices participating in a transfer will
> >> + * timeout when any clock low exceeds the value of
> >> + * T_TIMEOUT,MIN of 25 ms."
> >> + */
> >
> > SMBus has that timeout, but I2C doesn't. How about disabling the timeout
> > simply? Or using the max value if you want to keep the timeout
> > detection?
>
> Disabling the timeout seems fine to me. We still have a 1-second
> timeout around the entire transfer. I'll be back on my DSI branch this
> week and test it out then.
Did it work?