Re: [PATCH] power:bq27xxx: 27000/10 read FLAGS register as single

From: Sebastian Reichel
Date: Mon Aug 15 2016 - 15:28:01 EST


Hi,

On Mon, Jul 18, 2016 at 06:12:09PM +0200, H. Nikolaus Schaller wrote:
> The bq27000 and bq27010 have a single byte FLAGS register.
> Other gauges have 16 bit FLAGS registers.
>
> For reading the FLAGS register it is sufficient to read the single
> register instead of reading RSOC at the next higher address as
> well and then ignore the high byte.
>
> This does not change functionality but optimizes i2c and hdq
> traffic.

Thanks, queued into power-supply's -next branch.

-- Sebastian

Attachment: signature.asc
Description: PGP signature