[PATHC v2 9/9] ima: platform-independent hash value

From: Mimi Zohar
Date: Tue Aug 30 2016 - 18:41:40 EST


From: Andreas Steffen <andreas.steffen@xxxxxxxxxxxxxx>

For remote attestion it is important for the ima measurement values
to be platform-independent. Therefore integer fields to be hashed
must be converted to canonical format.

Changelog:
- Define canonical format as little endian (Mimi)

Signed-off-by: Andreas Steffen <andreas.steffen@xxxxxxxxxxxxxx>
Signed-off-by: Mimi Zohar <zohar@xxxxxxxxxxxxxxxxxx>
---
security/integrity/ima/ima_crypto.c | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)

diff --git a/security/integrity/ima/ima_crypto.c b/security/integrity/ima/ima_crypto.c
index 38f2ed8..38d6f5d 100644
--- a/security/integrity/ima/ima_crypto.c
+++ b/security/integrity/ima/ima_crypto.c
@@ -477,11 +477,13 @@ static int ima_calc_field_array_hash_tfm(struct ima_field_data *field_data,
u8 buffer[IMA_EVENT_NAME_LEN_MAX + 1] = { 0 };
u8 *data_to_hash = field_data[i].data;
u32 datalen = field_data[i].len;
+ u32 datalen_to_hash = !ima_canonical_fmt ? datalen :
+ cpu_to_le32(datalen);

if (strcmp(td->name, IMA_TEMPLATE_IMA_NAME) != 0) {
rc = crypto_shash_update(shash,
- (const u8 *) &field_data[i].len,
- sizeof(field_data[i].len));
+ (const u8 *) &datalen_to_hash,
+ sizeof(datalen_to_hash));
if (rc)
break;
} else if (strcmp(td->fields[i]->field_id, "n") == 0) {
--
2.1.0