Re: [PATCH v3 1/2] regulator: pwm: Add support for a fixed delay after duty cycle changes

From: Mark Brown
Date: Thu Sep 01 2016 - 17:09:52 EST


On Tue, Aug 30, 2016 at 09:21:15PM -0700, Douglas Anderson wrote:

> A change of the duty cycle doesn't necessarily cause an immediate switch
> to the target voltage. On many PWM regulators there is a fixed "settle
> time" (irrespective of the jump size) that we need to wait after an
> upward jump. This change introduces the device tree property
> "settle-time-up-us" which allows us to specify a fixed delay after a
> voltage increase.

Why is this specific to regulators implemented with PWM controllers?
Most DCDCs have a PWM element and the concept of a hard time limit for
transition rather than a ramp rate doesn't seem like it'd be unique.

Attachment: signature.asc