On some newer Allwinner SoCs (H3 or A64), the PHY0 can be either routed to
the MUSB controller (which is an OTG controller) or the OHCI/EHCI pair
(which is a Host-only controller, but more stable and easy to implement).
This property marks whether on a certain board which controller should be
attached to the PHY.
Signed-off-by: Icenowy Zheng <icenowy@xxxxxxxx>
---
Documentation/devicetree/bindings/phy/sun4i-usb-phy.txt | 6 ++++++
1 file changed, 6 insertions(+)
diff --git a/Documentation/devicetree/bindings/phy/sun4i-usb-phy.txt b/Documentation/devicetree/bindings/phy/sun4i-usb-phy.txt
index 287150d..a63c766 100644
--- a/Documentation/devicetree/bindings/phy/sun4i-usb-phy.txt
+++ b/Documentation/devicetree/bindings/phy/sun4i-usb-phy.txt
@@ -36,6 +36,12 @@ Optional properties:
- usb1_vbus-supply : regulator phandle for controller usb1 vbus
- usb2_vbus-supply : regulator phandle for controller usb2 vbus
+Optional properties for H3 or A64 SoCs:
+- allwinner,otg-routed : USB0 (OTG) PHY is routed to OHCI/EHCI pair rather than
+ MUSB. (boolean, if this property is set, the OHCI/EHCI
+ controllers at PHY0 should be enabled and the MUSB
+ controller must *NOT* be enabled)
+
Example:
usbphy: phy@0x01c13400 {
#phy-cells = <1>;