[PATCH 4.4 088/112] bnx2x: Prevent false warning for lack of FC NPIV

From: Greg Kroah-Hartman
Date: Wed Oct 26 2016 - 08:49:29 EST


4.4-stable review patch. If anyone has any objections, please let me know.

------------------

From: Yuval Mintz <Yuval.Mintz@xxxxxxxxxx>

commit 1e6bb1a3540fec3ef112b9a89dda88e684c3ff59 upstream.

Not all adapters have FC-NPIV configured. If bnx2fc is used with such an
adapter, driver would read irrelevant data from the the nvram and log
"FC-NPIV table with bad length..." In system logs.

Simply accept that reading '0' as the feature offset in nvram indicates
the feature isn't there and return.

Reported-by: Andrew Patterson <andrew.patterson@xxxxxxx>
Signed-off-by: Yuval Mintz <Yuval.Mintz@xxxxxxxxxx>
Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
Signed-off-by: Juerg Haefliger <juerg.haefliger@xxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c | 4 ++++
1 file changed, 4 insertions(+)

--- a/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
+++ b/drivers/net/ethernet/broadcom/bnx2x/bnx2x_main.c
@@ -14819,6 +14819,10 @@ static int bnx2x_get_fc_npiv(struct net_
}

offset = SHMEM2_RD(bp, fc_npiv_nvram_tbl_addr[BP_PORT(bp)]);
+ if (!offset) {
+ DP(BNX2X_MSG_MCP, "No FC-NPIV in NVRAM\n");
+ goto out;
+ }
DP(BNX2X_MSG_MCP, "Offset of FC-NPIV in NVRAM: %08x\n", offset);

/* Read the table contents from nvram */