Re: [PATCH v2 09/23] staging: iio: tsl2583: cleaned up logging

From: Joe Perches
Date: Tue Nov 08 2016 - 05:29:34 EST


On Tue, 2016-11-08 at 05:16 -0500, Brian Masney wrote:
> There are several places in the code where the function name is
> hardcoded in the log message. Use the __func__ constant string to build
> the log message. This also clarifies some of the error messages to match
> the code and ensures that the correct priority is used since the message
> is already being changed.
[]
> diff --git a/drivers/staging/iio/light/tsl2583.c b/drivers/staging/iio/light/tsl2583.c
[]
> @@ -170,13 +170,15 @@ static int taos_get_lux(struct iio_dev *indio_dev)
>
> ret = i2c_smbus_read_byte_data(chip->client, TSL258X_CMD_REG);
> if (ret < 0) {
> - dev_err(&chip->client->dev, "taos_get_lux failed to read CMD_REG\n");
> + dev_err(&chip->client->dev, "%s failed to read CMD_REG register\n",
> + __func__);

Please use "%s: <message>", __func__ consistently

> @@ -545,12 +549,15 @@ static ssize_t in_illuminance_lux_table_store(struct device *dev,
> * and the last table entry is all 0.
> */
> n = value[0];
> - if ((n % 3) || n < 6 || n > ((ARRAY_SIZE(taos_device_lux) - 1) * 3)) {
> - dev_info(dev, "LUX TABLE INPUT ERROR 1 Value[0]=%d\n", n);
> + if ((n % 3) || n < 6 || n > TSL2583_MAX_LUX_INTS) {
> + dev_err(dev,
> + "%s: The number of entries in the lux table must be a multiple of 3 and within the range [6, %zu]",
> + __func__, TSL2583_MAX_LUX_INTS);

Missing terminating '\n"