Re: [PATCH V3 1/9] PM / OPP: Reword binding supporting multiple regulators per device

From: Mark Brown
Date: Wed Nov 09 2016 - 09:58:56 EST


On Wed, Oct 26, 2016 at 12:02:56PM +0530, Viresh Kumar wrote:

> + Entries for multiple regulators shall be provided in the same field separated
> + by angular brackets <>. The OPP binding doesn't provide any provisions to
> + relate the values to their power supplies or the order in which the supplies
> + need to be configured.

I don't understand how this works. If we have an unordered list of
values to set for regulators how will we make sense of them?

> - cpu-supply = <&cpu_supply0>, <&cpu_supply1>, <&cpu_supply2>;
> + vcc0-supply = <&cpu_supply0>;
> + vcc1-supply = <&cpu_supply1>;
> + vcc2-supply = <&cpu_supply2>;

This change doesn't seem to correspond to the documentation change.

Attachment: signature.asc
Description: PGP signature