Re: [PATCH] reset: hisilicon: add a polarity cell for reset line specifier

From: Jiancheng Xue
Date: Thu Nov 24 2016 - 22:46:38 EST



On 2016/11/21 10:58, Jiancheng Xue wrote:
> Hi Philipp,
>
>> On 2016/11/15 18:43, Philipp Zabel wrote:
>>> Hi Jiancheng,
>>>
>>> Am Dienstag, den 15.11.2016, 15:09 +0800 schrieb Jiancheng Xue:
>>>> Add a polarity cell for reset line specifier. If the reset line
>>>> is asserted when the register bit is 1, the polarity is
>>>> normal. Otherwise, it is inverted.
>>>>
>>>> Signed-off-by: Jiancheng Xue <xuejiancheng@xxxxxxxxxxxxx>
>>>> ---
>> Thank you very much for replying so soon.
>>
>> Please allow me to decribe the reason why this patch exists first.
>> All bits in the reset controller were designed to be active-high.
>> But in a recent chip only one bit was implemented to be active-low :(
>>
>>>> .../devicetree/bindings/clock/hisi-crg.txt | 11 ++++---
>>>> arch/arm/boot/dts/hi3519.dtsi | 2 +-
>>>> drivers/clk/hisilicon/reset.c | 36 ++++++++++++++++------
>>>> 3 files changed, 33 insertions(+), 16 deletions(-)
>>>>
>>>> diff --git a/Documentation/devicetree/bindings/clock/hisi-crg.txt b/Documentation/devicetree/bindings/clock/hisi-crg.txt
>>>> index e3919b6..fcbb4f3 100644
>>>> --- a/Documentation/devicetree/bindings/clock/hisi-crg.txt
>>>> +++ b/Documentation/devicetree/bindings/clock/hisi-crg.txt
>>>> @@ -25,19 +25,20 @@ to specify the clock which they consume.
>>>>
>>>> All these identifier could be found in <dt-bindings/clock/hi3519-clock.h>.
>>>>
>>>> -- #reset-cells: should be 2.
>>>> +- #reset-cells: should be 3.
>>>>
>>>> A reset signal can be controlled by writing a bit register in the CRG module.
>>>> -The reset specifier consists of two cells. The first cell represents the
>>>> +The reset specifier consists of three cells. The first cell represents the
>>>> register offset relative to the base address. The second cell represents the
>>>> -bit index in the register.
>>>> +bit index in the register. The third cell represents the polarity of the reset
>>>> +line (0 for normal, 1 for inverted).
>>>
> #reset-cells: Should be 2 if compatilbe string is "hisilicon,hi3519-crg". Should be 3 otherwise.
> A reset signal can be controlled by writing a bit register in the CRG module.
> The reset specifier consists of two or three cells. The first cell represents the
> register offset relative to the base address. The second cell represents the
> bit index in the register.The third cell represents the polarity of the reset
> line (0 for active-high, 1 for active-low).
>
> If I change the binding like this, can it be accepted?
>
Hi Philipp,

Could you give me more suggestions about this? If you really don't like changing the
reset-cells like this, I can modify the patch according to your suggestions.
Thank you.

Regards,