Re: bnx2 breaks Dell R815 BMC IPMI since 4.8
From: Brice Goglin
Date: Wed Nov 30 2016 - 01:27:07 EST
Le 30 novembre 2016 00:28:08 GMT+01:00, Gavin Shan <gwshan@xxxxxxxxxxxxxxxxxx> a Ãcrit :
>On Tue, Nov 29, 2016 at 07:57:51AM +0100, Brice Goglin wrote:
>>Hello
>>
>>My Dell PowerEdge R815 doesn't have IPMI anymore when I boot a 4.8
>>kernel, the BMC doesn't even ping anymore. Its Ethernet devices are 4
>of
>>those:
>>
>>01:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM5709
>Gigabit Ethernet (rev 20)
>> DeviceName: Embedded NIC 1
>> Subsystem: Dell NetXtreme II BCM5709 Gigabit Ethernet
>> Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr-
>Stepping- SERR- FastB2B- DisINTx+
>> Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort-
><TAbort- <MAbort- >SERR- <PERR- INTx-
>> Latency: 0, Cache Line Size: 64 bytes
>> Interrupt: pin A routed to IRQ 42
>> Region 0: Memory at e6000000 (64-bit, non-prefetchable) [size=32M]
>> Capabilities: <access denied>
>> Kernel driver in use: bnx2
>> Kernel modules: bnx2
>>
>>The only change in bnx2 between 4.7 and 4.8 appears to be this one:
>>
>>commit 3e1be7ad2d38c6bd6aeef96df9bd0a7822f4e51c
>>Author: Baoquan He <bhe@xxxxxxxxxx>
>>Date: Fri Sep 9 22:43:12 2016 +0800
>>
>> bnx2: Reset device during driver initialization
>>
>>Could you patch actually break the BMC? What do I need to further
>debug
>>this issue?
>>
>
>Brice, could you please confirm NCSI is enabled on BMC? It seems NCSI
>AEN pakets aren't handled by NCSI stack on BMC side when resetting NIC
>on host side. Those AEN packets usually help to reconfigure the
>(active)
>NCSI channel and bring it back to service after the reset.
I don't remember ever seeing the name NCSI in those Dell BMC configs. Any other word to look for?
By the way, the bug is gone in 4.8.11.
Brice