Re: [RFC v2 0/4] ACPI: SPCR: 32-bit access and non-standard baud rate
From: Jon Masters
Date: Tue Dec 06 2016 - 13:21:04 EST
Hi Aleksey,
On 12/06/2016 12:58 PM, Aleksey Makarov wrote:
> It turns out that this approach does not work for all the existing hardware.
> There are two problems with AppliedMicro X-Gene based boards
> ([discussion], [v1]):
>
> 1. Their console is a 16550 port that requires 32-bit access. Now SPCR does not
> have any method to specify this.
>
> 2. Some of the boards don't use the "standard" 16550 clock rate so supplying
> a baud rate makes it change to a random baud rate.
>
> Patch 1/4 uses 'Register Bit Width' field of the ACPI Generic Address
> Structure that specifies the address of the UART registers to
> decide if the driver should use "mmio32" access instead of "mmio".
> This fixes problem 1 for existing hardware/firmware.
>
> To fix problem 2, I suggest to introduce a new value '0' for the "Baud Rate"
> field of SPCR (now this value is reserved). I would like to discuss if this
> could be added to SPCR spec and will fix the problem.
Part 1 could well be solved in this way, provided it can be made part
of the mainstream specification. It seems fairly reasonable, however.
I'm not sure I subscribe to part 2 because there could be all manner
of havoc changing the interpretation of existing zero values. That is
why I personally favor an AppliedMicro SPCR subtype specific to them.
That all said, I did discuss exactly part 2 with the folks responsible
for the SPCR specification and they are thinking about their preferred
solution, which will likely either be a new subtype for Applied, or
perhaps allow for what you describe. I will followup when I know.
Jon.
--
Computer Architect | Sent from my Fedora powered laptop