[PATCH 4.9 050/206] USB: serial: io_ti: fix I/O after disconnect
From: Greg Kroah-Hartman
Date: Tue Jan 10 2017 - 08:45:43 EST
4.9-stable review patch. If anyone has any objections, please let me know.
------------------
From: Johan Hovold <johan@xxxxxxxxxx>
commit 2330d0a853da260d8a9834a70df448032b9ff623 upstream.
Cancel the heartbeat work on driver unbind in order to avoid I/O after
disconnect in case the port is held open.
Note that the cancel in release() is still needed to stop the heartbeat
after late probe errors.
Fixes: 26c78daade0f ("USB: io_ti: Add heartbeat to keep idle EP/416 ports from disconnecting")
Signed-off-by: Johan Hovold <johan@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/usb/serial/io_ti.c | 3 +++
1 file changed, 3 insertions(+)
--- a/drivers/usb/serial/io_ti.c
+++ b/drivers/usb/serial/io_ti.c
@@ -2593,6 +2593,9 @@ static int edge_startup(struct usb_seria
static void edge_disconnect(struct usb_serial *serial)
{
+ struct edgeport_serial *edge_serial = usb_get_serial_data(serial);
+
+ cancel_delayed_work_sync(&edge_serial->heartbeat_work);
}
static void edge_release(struct usb_serial *serial)