[PATCH v17 2/7] drm/rockchip: cdn-dp: Load firmware if no monitor connected
From: Chris Zhong
Date: Sun Feb 05 2017 - 02:57:59 EST
From: Guenter Roeck <groeck@xxxxxxxxxxxx>
If no monitor is connected, suspend/resume cycles result in firmware
load errors because the driver attempts to load the firmware while
the system is in suspend state. This results in a kernel warning and
traceback.
Loading the firmware during boot fixes the problem. Note that we can not
just call schedule_work conditionally in cdn_dp_pd_event() if the insertion
status changed. The problem would still be seen if a monitor is connected
for the first time during suspend.
Signed-off-by: Guenter Roeck <groeck@xxxxxxxxxxxx>
Signed-off-by: Sean Paul <seanpaul@xxxxxxxxxxxx>
Signed-off-by: Chris Zhong <zyw@xxxxxxxxxxxxxx>
---
Changes in v17: None
drivers/gpu/drm/rockchip/cdn-dp-core.c | 7 +------
1 file changed, 1 insertion(+), 6 deletions(-)
diff --git a/drivers/gpu/drm/rockchip/cdn-dp-core.c b/drivers/gpu/drm/rockchip/cdn-dp-core.c
index 7db2508..b8d0dd7 100644
--- a/drivers/gpu/drm/rockchip/cdn-dp-core.c
+++ b/drivers/gpu/drm/rockchip/cdn-dp-core.c
@@ -1021,7 +1021,6 @@ static int cdn_dp_bind(struct device *dev, struct device *master, void *data)
struct cdn_dp_port *port;
struct drm_device *drm_dev = data;
int ret, i;
- bool schedule_event = false;
ret = cdn_dp_parse_dt(dp);
if (ret < 0)
@@ -1083,15 +1082,11 @@ static int cdn_dp_bind(struct device *dev, struct device *master, void *data)
"register EXTCON_DISP_DP notifier err\n");
goto err_free_connector;
}
-
- if (extcon_get_state(port->extcon, EXTCON_DISP_DP))
- schedule_event = true;
}
pm_runtime_enable(dev);
- if (schedule_event)
- schedule_work(&dp->event_work);
+ schedule_work(&dp->event_work);
return 0;
--
2.6.3