[PATCH 3.16 022/370] scsi: megaraid_sas: For SRIOV enabled firmware, ensure VF driver waits for 30secs before reset
From: Ben Hutchings
Date: Fri Mar 10 2017 - 06:51:47 EST
3.16.42-rc1 review patch. If anyone has any objections, please let me know.
------------------
From: Kashyap Desai <kashyap.desai@xxxxxxxxxxxx>
commit 18e1c7f68a5814442abad849abe6eacbf02ffd7c upstream.
For SRIOV enabled firmware, if there is a OCR(online controller reset)
possibility driver set the convert flag to 1, which is not happening if
there are outstanding commands even after 180 seconds. As driver does
not set convert flag to 1 and still making the OCR to run, VF(Virtual
function) driver is directly writing on to the register instead of
waiting for 30 seconds. Setting convert flag to 1 will cause VF driver
will wait for 30 secs before going for reset.
Signed-off-by: Kiran Kumar Kasturi <kiran-kumar.kasturi@xxxxxxxxxxxx>
Signed-off-by: Sumit Saxena <sumit.saxena@xxxxxxxxxxxx>
Reviewed-by: Hannes Reinecke <hare@xxxxxxxx>
Reviewed-by: Tomas Henzl <thenzl@xxxxxxxxxx>
Signed-off-by: Martin K. Petersen <martin.petersen@xxxxxxxxxx>
Signed-off-by: Ben Hutchings <ben@xxxxxxxxxxxxxxx>
---
drivers/scsi/megaraid/megaraid_sas_fusion.c | 1 +
1 file changed, 1 insertion(+)
--- a/drivers/scsi/megaraid/megaraid_sas_fusion.c
+++ b/drivers/scsi/megaraid/megaraid_sas_fusion.c
@@ -2291,6 +2291,7 @@ int megasas_wait_for_outstanding_fusion(
printk("megaraid_sas: pending commands remain after waiting, "
"will reset adapter scsi%d.\n",
instance->host->host_no);
+ *convert = 1;
retval = 1;
}
out: