[PATCH v4 1/5] dt-bindings: update device tree binding for Allwinner PRCM CCUs

From: Icenowy Zheng
Date: Tue Apr 04 2017 - 05:55:18 EST


From: Icenowy Zheng <icenowy@xxxxxxxx>

Many Allwinner SoCs after A31 have a CCU in PRCM block.

Give the ones on H3 and A64 compatible strings.

Signed-off-by: Icenowy Zheng <icenowy@xxxxxxxx>
Acked-by: Rob Herring <robh@xxxxxxxxxx>
---
Changes in v4:
- Add Rob's ACK.
Changes in v3:
- Removed frequency info of iosc in this device tree binding document.
Changes in v2:
- Add iosc for R_CCU's on H3/A64.

Documentation/devicetree/bindings/clock/sunxi-ccu.txt | 17 ++++++++++++++++-
1 file changed, 16 insertions(+), 1 deletion(-)

diff --git a/Documentation/devicetree/bindings/clock/sunxi-ccu.txt b/Documentation/devicetree/bindings/clock/sunxi-ccu.txt
index 68512aa398a9..e9c5a1d9834a 100644
--- a/Documentation/devicetree/bindings/clock/sunxi-ccu.txt
+++ b/Documentation/devicetree/bindings/clock/sunxi-ccu.txt
@@ -7,9 +7,11 @@ Required properties :
- "allwinner,sun8i-a23-ccu"
- "allwinner,sun8i-a33-ccu"
- "allwinner,sun8i-h3-ccu"
+ - "allwinner,sun8i-h3-r-ccu"
- "allwinner,sun8i-v3s-ccu"
- "allwinner,sun9i-a80-ccu"
- "allwinner,sun50i-a64-ccu"
+ - "allwinner,sun50i-a64-r-ccu"
- "allwinner,sun50i-h5-ccu"

- reg: Must contain the registers base address and length
@@ -20,7 +22,10 @@ Required properties :
- #clock-cells : must contain 1
- #reset-cells : must contain 1

-Example:
+For the PRCM CCUs on H3/A64, one more clock is needed:
+- "iosc": the SoC's internal frequency oscillator
+
+Example for generic CCU:
ccu: clock@01c20000 {
compatible = "allwinner,sun8i-h3-ccu";
reg = <0x01c20000 0x400>;
@@ -29,3 +34,13 @@ ccu: clock@01c20000 {
#clock-cells = <1>;
#reset-cells = <1>;
};
+
+Example for PRCM CCU:
+r_ccu: clock@01f01400 {
+ compatible = "allwinner,sun50i-a64-r-ccu";
+ reg = <0x01f01400 0x100>;
+ clocks = <&osc24M>, <&osc32k>, <&iosc>;
+ clock-names = "hosc", "losc", "iosc";
+ #clock-cells = <1>;
+ #reset-cells = <1>;
+};
--
2.12.2