[PATCH v2 1/2] dt-binding: regulator: anatop: make regulator name property required

From: Dong Aisheng
Date: Fri Apr 14 2017 - 10:34:20 EST


We actually can't allow the missing of the regualor name, thus update
the binding doc to make regulator-name property to be required.

Cc: Rob Herring <robh+dt@xxxxxxxxxx>
Cc: Mark Rutland <mark.rutland@xxxxxxx>
Cc: devicetree@xxxxxxxxxxxxxxx
Signed-off-by: Dong Aisheng <aisheng.dong@xxxxxxx>
---
Documentation/devicetree/bindings/regulator/anatop-regulator.txt | 1 +
1 file changed, 1 insertion(+)

diff --git a/Documentation/devicetree/bindings/regulator/anatop-regulator.txt b/Documentation/devicetree/bindings/regulator/anatop-regulator.txt
index 1d58c8c..a3106c7 100644
--- a/Documentation/devicetree/bindings/regulator/anatop-regulator.txt
+++ b/Documentation/devicetree/bindings/regulator/anatop-regulator.txt
@@ -2,6 +2,7 @@ Anatop Voltage regulators

Required properties:
- compatible: Must be "fsl,anatop-regulator"
+- regulator-name: A string used as a descriptive name for regulator outputs
- anatop-reg-offset: Anatop MFD register offset
- anatop-vol-bit-shift: Bit shift for the register
- anatop-vol-bit-width: Number of bits used in the register
--
2.7.4