Re: [PATCH] microblaze/timer: set ->min_delta_ticks and ->max_delta_ticks

From: Nicolai Stange
Date: Sat Apr 15 2017 - 22:47:48 EST


Hello Daniel,

On Fri, Apr 07 2017, Daniel Lezcano wrote:

> On Thu, Mar 30, 2017 at 09:45:28PM +0200, Nicolai Stange wrote:
>> diff --git a/arch/microblaze/kernel/timer.c b/arch/microblaze/kernel/timer.c
>> index 999066192715..545ccd46edb3 100644
>> --- a/arch/microblaze/kernel/timer.c
>> +++ b/arch/microblaze/kernel/timer.c
>> @@ -178,8 +178,10 @@ static __init int xilinx_clockevent_init(void)
>> clockevent_xilinx_timer.shift);
>> clockevent_xilinx_timer.max_delta_ns =
>> clockevent_delta2ns((u32)~0, &clockevent_xilinx_timer);
>> + clockevent_xilinx_timer.max_delta_ticks = (u32)~0;
>
> Can you take the opportunity to fix the type (unsigned long) ?

Hmm, I personally think that it'd be better to leave the u32 there as it
corresponds to the hardware's counter width?

clockevent_delta2ns()' latch argument has been of type unsigned long
from the beginning and this might indicate that at least this
driver's original author followed this line of reasoning...

OTOH, I think that u32 is equivalent to unsigned long on microblaze, so
it doesn't matter much.

Does the above convince you or do you still want the

- clockevent_xilinx_timer.max_delta_ticks = (u32)~0;
+ clockevent_xilinx_timer.max_delta_ticks = ~0UL;

change?


Thanks,

Nicolai