Re: [PATCH net-next 11/18] net: dsa: mv88e6xxx: get STU entry on VTU GetNext
From: Andrew Lunn
Date: Thu Apr 27 2017 - 16:17:53 EST
On Wed, Apr 26, 2017 at 11:53:29AM -0400, Vivien Didelot wrote:
> Now that the code reads both VTU and STU data on VTU GetNext operation,
> fetch the STU entry data of a VTU entry at the same time.
>
> The STU data bits are masked with the VTU data bits and they are now all
> read at the same time a VTU GetNext operation is issued.
>
> Signed-off-by: Vivien Didelot <vivien.didelot@xxxxxxxxxxxxxxxxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
Andrew