Re: [PATCH] input: edt-ft5x06: increase allowed data range for threshold parameter
From: Martin Kepplinger
Date: Wed May 17 2017 - 08:39:34 EST
On 2017-05-11 10:32, Martin Kepplinger wrote:
> On 2017-05-08 18:11, Rob Herring wrote:
>> On Tue, May 02, 2017 at 05:00:59PM +0200, Martin Kepplinger wrote:
>>> The datasheet and application note does not mention an allowed range for
>>> the M09_REGISTER_THRESHOLD parameter. One of our customers needs to set
>>> lower values than 20 and they seem to work just fine on EDT EP0xx0M09 with
>>> T5x06 touch.
>>>
>>> So, lacking a known lower limit, we increase the range for thresholds,
>>> and set the lower limit to 0. The documentation is updated accordingly.
>>>
>>> Signed-off-by: Schoefegger Stefan <stefan.schoefegger@xxxxxxxxxxxxx>
>>> Signed-off-by: Manfred Schlaegl <manfred.schlaegl@xxxxxxxxxxxxx>
>>> Signed-off-by: Martin Kepplinger <martin.kepplinger@xxxxxxxxxxxxx>
>>> ---
>>> Documentation/devicetree/bindings/input/touchscreen/edt-ft5x06.txt | 2 +-
>>> Documentation/input/devices/edt-ft5x06.rst | 2 +-
>>> drivers/input/touchscreen/edt-ft5x06.c | 2 +-
>>> 3 files changed, 3 insertions(+), 3 deletions(-)
>>
>> Acked-by: Rob Herring <robh@xxxxxxxxxx>
>>
>
> Dmitry, any objections or thoughts?
Hey Dmitry, this still applies to today's -next and wouldn't take too
long for you to review :)
thanks
martin