Re: [PATCH V4 03/17] thermal: cpu_cooling: Name cpufreq cooling devices as cpufreq_cdev

From: Zhang Rui
Date: Tue May 23 2017 - 02:37:59 EST


On Tue, 2017-04-25 at 15:57 +0530, Viresh Kumar wrote:
> Objects of "struct cpufreq_cooling_device" are named a bit
> inconsistently. Lets use cpufreq_cdev everywhere. Also note that the
> lists containing such devices is renamed similarly too.
>
> Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx>
> Tested-by: Lukasz Luba <lukasz.luba@xxxxxxx>
> ---
> Âdrivers/thermal/cpu_cooling.c | 248 +++++++++++++++++++++-----------
> ----------
> Â1 file changed, 124 insertions(+), 124 deletions(-)
>
>

> Â
> Â num_cpus = cpumask_weight(clip_cpus);
> - cpufreq_dev->time_in_idle = kcalloc(num_cpus,
> - ÂÂÂÂsizeof(*cpufreq_dev-
> >time_in_idle),
> + cpufreq_cdev->time_in_idle = kcalloc(num_cpus,
> + ÂÂÂÂsizeof(*cpufreq_cdev-
> >time_in_idle),
> Â ÂÂÂÂGFP_KERNEL);

checkpatch complains about this line

WARNING: Prefer kmalloc_array over kmalloc with multiply
#544: FILE: drivers/thermal/cpu_cooling.c:827:
+ cpufreq_cdev->freq_table = kmalloc(sizeof(*cpufreq_cdev-
>freq_table) *
+ ÂÂcpufreq_cdev->max_level,
GFP_KERNEL);

total: 0 errors, 1 warnings, 614 lines checked

NOTE: For some of the reported defects, checkpatch may be able to
ÂÂÂÂÂÂmechanically convert to the typical style using --fix or --fix-
inplace.

and also patch 8/17.

It's better to get this fixed.

thanks,
rui


> - if (!cpufreq_dev->time_in_idle) {
> + if (!cpufreq_cdev->time_in_idle) {
> Â cool_dev = ERR_PTR(-ENOMEM);
> Â goto free_cdev;
> Â }
> Â
> - cpufreq_dev->time_in_idle_timestamp =
> - kcalloc(num_cpus, sizeof(*cpufreq_dev-
> >time_in_idle_timestamp),
> + cpufreq_cdev->time_in_idle_timestamp =
> + kcalloc(num_cpus, sizeof(*cpufreq_cdev-
> >time_in_idle_timestamp),
> Â GFP_KERNEL);
> - if (!cpufreq_dev->time_in_idle_timestamp) {
> + if (!cpufreq_cdev->time_in_idle_timestamp) {
> Â cool_dev = ERR_PTR(-ENOMEM);
> Â goto free_time_in_idle;
> Â }
> Â
> Â /* Find max levels */
> Â cpufreq_for_each_valid_entry(pos, table)
> - cpufreq_dev->max_level++;
> + cpufreq_cdev->max_level++;
> Â
> - cpufreq_dev->freq_table = kmalloc(sizeof(*cpufreq_dev-
> >freq_table) *
> - ÂÂcpufreq_dev->max_level,
> GFP_KERNEL);
> - if (!cpufreq_dev->freq_table) {
> + cpufreq_cdev->freq_table = kmalloc(sizeof(*cpufreq_cdev-
> >freq_table) *
> + ÂÂcpufreq_cdev->max_level,
> GFP_KERNEL);
> + if (!cpufreq_cdev->freq_table) {
> Â cool_dev = ERR_PTR(-ENOMEM);
> Â goto free_time_in_idle_timestamp;
> Â }
> Â
> Â /* max_level is an index, not a counter */
> - cpufreq_dev->max_level--;
> + cpufreq_cdev->max_level--;
> Â
> - cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
> + cpumask_copy(&cpufreq_cdev->allowed_cpus, clip_cpus);
> Â
> Â if (capacitance) {
> - cpufreq_dev->plat_get_static_power =
> plat_static_func;
> + cpufreq_cdev->plat_get_static_power =
> plat_static_func;
> Â
> - ret = build_dyn_power_table(cpufreq_dev,
> capacitance);
> + ret = build_dyn_power_table(cpufreq_cdev,
> capacitance);
> Â if (ret) {
> Â cool_dev = ERR_PTR(ret);
> Â goto free_table;
> @@ -856,12 +855,12 @@ __cpufreq_cooling_register(struct device_node
> *np,
> Â cool_dev = ERR_PTR(ret);
> Â goto free_power_table;
> Â }
> - cpufreq_dev->id = ret;
> + cpufreq_cdev->id = ret;
> Â
> Â /* Fill freq-table in descending order of frequencies */
> - for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
> + for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) {
> Â freq = find_next_max(table, freq);
> - cpufreq_dev->freq_table[i] = freq;
> + cpufreq_cdev->freq_table[i] = freq;
> Â
> Â /* Warn for duplicate entries */
> Â if (!freq)
> @@ -871,20 +870,21 @@ __cpufreq_cooling_register(struct device_node
> *np,
> Â }
> Â
> Â snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
> - Âcpufreq_dev->id);
> + Âcpufreq_cdev->id);
> Â
> - cool_dev = thermal_of_cooling_device_register(np, dev_name,
> cpufreq_dev,
> + cool_dev = thermal_of_cooling_device_register(np, dev_name,
> + ÂÂÂÂÂÂcpufreq_cdev,
> Â ÂÂÂÂÂÂcooling_ops);
> Â if (IS_ERR(cool_dev))
> Â goto remove_ida;
> Â
> - cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
> - cpufreq_dev->cool_dev = cool_dev;
> + cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0];
> + cpufreq_cdev->cool_dev = cool_dev;
> Â
> Â mutex_lock(&cooling_list_lock);
> Â /* Register the notifier for first cpufreq cooling device */
> - first = list_empty(&cpufreq_dev_list);
> - list_add(&cpufreq_dev->node, &cpufreq_dev_list);
> + first = list_empty(&cpufreq_cdev_list);
> + list_add(&cpufreq_cdev->node, &cpufreq_cdev_list);
> Â mutex_unlock(&cooling_list_lock);
> Â
> Â if (first)
> @@ -894,17 +894,17 @@ __cpufreq_cooling_register(struct device_node
> *np,
> Â goto put_policy;
> Â
> Âremove_ida:
> - ida_simple_remove(&cpufreq_ida, cpufreq_dev->id);
> + ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
> Âfree_power_table:
> - kfree(cpufreq_dev->dyn_power_table);
> + kfree(cpufreq_cdev->dyn_power_table);
> Âfree_table:
> - kfree(cpufreq_dev->freq_table);
> + kfree(cpufreq_cdev->freq_table);
> Âfree_time_in_idle_timestamp:
> - kfree(cpufreq_dev->time_in_idle_timestamp);
> + kfree(cpufreq_cdev->time_in_idle_timestamp);
> Âfree_time_in_idle:
> - kfree(cpufreq_dev->time_in_idle);
> + kfree(cpufreq_cdev->time_in_idle);
> Âfree_cdev:
> - kfree(cpufreq_dev);
> + kfree(cpufreq_cdev);
> Âput_policy:
> Â cpufreq_cpu_put(policy);
> Âfree_cpumask:
> @@ -1029,30 +1029,30 @@
> EXPORT_SYMBOL(of_cpufreq_power_cooling_register);
> Â */
> Âvoid cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
> Â{
> - struct cpufreq_cooling_device *cpufreq_dev;
> + struct cpufreq_cooling_device *cpufreq_cdev;
> Â bool last;
> Â
> Â if (!cdev)
> Â return;
> Â
> - cpufreq_dev = cdev->devdata;
> + cpufreq_cdev = cdev->devdata;
> Â
> Â mutex_lock(&cooling_list_lock);
> - list_del(&cpufreq_dev->node);
> + list_del(&cpufreq_cdev->node);
> Â /* Unregister the notifier for the last cpufreq cooling
> device */
> - last = list_empty(&cpufreq_dev_list);
> + last = list_empty(&cpufreq_cdev_list);
> Â mutex_unlock(&cooling_list_lock);
> Â
> Â if (last)
> Â cpufreq_unregister_notifier(&thermal_cpufreq_notifie
> r_block,
> Â ÂÂÂÂCPUFREQ_POLICY_NOTIFIER)
> ;
> Â
> - thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
> - ida_simple_remove(&cpufreq_ida, cpufreq_dev->id);
> - kfree(cpufreq_dev->dyn_power_table);
> - kfree(cpufreq_dev->time_in_idle_timestamp);
> - kfree(cpufreq_dev->time_in_idle);
> - kfree(cpufreq_dev->freq_table);
> - kfree(cpufreq_dev);
> + thermal_cooling_device_unregister(cpufreq_cdev->cool_dev);
> + ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
> + kfree(cpufreq_cdev->dyn_power_table);
> + kfree(cpufreq_cdev->time_in_idle_timestamp);
> + kfree(cpufreq_cdev->time_in_idle);
> + kfree(cpufreq_cdev->freq_table);
> + kfree(cpufreq_cdev);
> Â}
> ÂEXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);