[PATCH 4.11 024/197] dm raid: select the Kconfig option CONFIG_MD_RAID0

From: Greg Kroah-Hartman
Date: Tue May 23 2017 - 18:31:32 EST


4.11-stable review patch. If anyone has any objections, please let me know.

------------------

From: Mikulas Patocka <mpatocka@xxxxxxxxxx>

commit 7b81ef8b14f80033e4a4168d199a0f5fd79b9426 upstream.

Since the commit 0cf4503174c1 ("dm raid: add support for the MD RAID0
personality"), the dm-raid subsystem can activate a RAID-0 array.
Therefore, add MD_RAID0 to the dependencies of DM_RAID, so that MD_RAID0
will be selected when DM_RAID is selected.

Fixes: 0cf4503174c1 ("dm raid: add support for the MD RAID0 personality")
Signed-off-by: Mikulas Patocka <mpatocka@xxxxxxxxxx>
Signed-off-by: Mike Snitzer <snitzer@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/md/Kconfig | 1 +
1 file changed, 1 insertion(+)

--- a/drivers/md/Kconfig
+++ b/drivers/md/Kconfig
@@ -365,6 +365,7 @@ config DM_LOG_USERSPACE
config DM_RAID
tristate "RAID 1/4/5/6/10 target"
depends on BLK_DEV_DM
+ select MD_RAID0
select MD_RAID1
select MD_RAID10
select MD_RAID456