Re: [PATCH v3 10/10] serial: exar: Add support for IOT2040 device

From: Jan Kiszka
Date: Sun May 28 2017 - 12:42:09 EST


On 2017-05-27 15:52, Andy Shevchenko wrote:
> On Fri, May 26, 2017 at 7:02 PM, Jan Kiszka <jan.kiszka@xxxxxxxxxxx> wrote:
>> This implements the setup of RS232 and the switch-over to RS485 or RS422
>> for the Siemens IOT2040. That uses an EXAR XR17V352 with external logic
>> to switch between the different modes. The external logic is controlled
>> via MPIO pins of the EXAR controller.
>>
>> Only pin 10 can be exported as GPIO on the IOT2040. It is connected to
>> an LED.
>>
>> As the XR17V352 used on the IOT2040 is not equipped with an external
>> EEPROM, it cannot present itself as IOT2040-variant via subvendor/
>> subdevice IDs. Thus, we have to check via DMI for the target platform.
>
>> static void *
>> -xr17v35x_register_gpio(struct pci_dev *pcidev, unsigned int first_pin,
>> - unsigned int npins)
>> +__xr17v35x_register_gpio(struct pci_dev *pcidev, unsigned int first_pin,
>> + unsigned int npins)
>
>> +static int xr17v35x_register_gpio(struct pci_dev *pcidev,
>> + struct uart_8250_port *port)
>> +{
>> + if (pcidev->vendor == PCI_VENDOR_ID_EXAR)
>> + port->port.private_data =
>> + __xr17v35x_register_gpio(pcidev, 0, 16);
>> +
>> + return 0;
>> +}
>
>> - if (pcidev->vendor == PCI_VENDOR_ID_EXAR)
>> - port->port.private_data =
>> - xr17v35x_register_gpio(pcidev, 0, 16);
>> + ret = platform->register_gpio(pcidev, port);
>> }
>
> Can't you move at least some of this to the patch where you move the check?
>

This change is unrelated to that patch.

What I can offer is a separate patch to factor this out, but I'm not
sure it would buy us much.

Jan

--
Siemens AG, Corporate Technology, CT RDA ITP SES-DE
Corporate Competence Center Embedded Linux