[PATCH v2 2/7] dt-bindings: ap806: do not depend anymore of the *-clock-output-names

From: Gregory CLEMENT
Date: Wed May 31 2017 - 10:08:57 EST


This patch updates the documentation according to the change made in the
patch "clk: mvebu: ap806: do not depend anymore of the
*-clock-output-names": the clock names are no more part of the binding.

Acked-by: Rob Herring <robh@xxxxxxxxxx>
Signed-off-by: Gregory CLEMENT <gregory.clement@xxxxxxxxxxxxxxxxxx>
---
Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt | 4 ----
1 file changed, 4 deletions(-)

diff --git a/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
index 8968371d84e2..3faab71dff9f 100644
--- a/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
+++ b/Documentation/devicetree/bindings/arm/marvell/ap806-system-controller.txt
@@ -21,15 +21,11 @@ Required properties:
"marvell,ap806-system-controller", "syscon"
- reg: register area of the AP806 system controller
- #clock-cells: must be set to 1
- - clock-output-names: must be defined to:
- "ap-cpu-cluster-0", "ap-cpu-cluster-1", "ap-fixed", "ap-mss"

Example:

syscon: system-controller@6f4000 {
compatible = "marvell,ap806-system-controller", "syscon";
#clock-cells = <1>;
- clock-output-names = "ap-cpu-cluster-0", "ap-cpu-cluster-1",
- "ap-fixed", "ap-mss";
reg = <0x6f4000 0x1000>;
};
--
git-series 0.9.1