Re: [PATCH] spi: pxa2xx: Only claim CS GPIOs when the slave device is created
From: Jan Kiszka
Date: Mon Jul 10 2017 - 13:32:37 EST
On 2017-07-10 14:09, Mark Brown wrote:
> On Sun, Jul 09, 2017 at 12:48:10AM +0300, Andy Shevchenko wrote:
>> On Sat, Jul 8, 2017 at 11:41 AM, Jan Kiszka <jan.kiszka@xxxxxx> wrote:
>
>>> Tested on the IOT2000 where the second SPI bus is connected to an
>>> Arduino-compatible connector and multiplexed between SPI, GPIO and PWM
>>> usage.
>
>> Can we first switch the driver to use GPIO descriptors instead of
>> plain integers?
>
> Only if you also convert the SPI core to use descriptors, Chris Packham
> was looking at that but he needed update the ep93xx drivers among others
> and getting reviewers was hard.
>
IIUC, we can't convert completely due to some legacy boards providing
their CS lines as integers. But even then, a few more API usages can be
converted.
While looking into this, I noticed that this patch violated the formal
rule to never release a GPIO with the old API when it was requested with
the new one. That's at least stated in the docs, even though gpio_free
is equivalent to gpiod_put. Fixed that already, but I need to find some
time to retest.
Jan
Attachment:
signature.asc
Description: OpenPGP digital signature